Installing the Rackify TP-Link TL-SG105 mount in a 19-inch rack

19-inch · 1U shelf · about 10 minutes

To install the Rackify TP-Link TL-SG105 mount in a 19-inch rack, join the two halves, push the switch in through the faceplate, back end first, then screw the shelf to the rack rails. It is a 1U shelf for standard 19-inch racks. Installing it takes about 10 minutes, with no brackets or device screws.

At a glance

MountTP-Link TL-SG105 1U 19-Inch Rack Mount
Rack19-inch (482.6 mm), 1U
FitsStandard 19-inch racks
Mount size (W × D × H)482.6 × 98.5 × 44.45 mm
TimeAbout 10 minutes
ToolsScrewdriver for your rack screws; Small screwdriver for the supplied device screws; Hex key for the M5 socket cap screws
In the box19-inch 1U halves printed in PETG, per your Placement: Left or Right = your module + a blank half; Both = two modules; half only = one half; 3 × M5 socket cap screws + 3 × M5 hex nuts (joins the two halves)
Not includedRack screws; Keystone jacks
  1. Step 1: Remove the feet, if attached

    If you stuck the rubber feet on the bottom of the switch, peel them off. The shelf is sized to the bare case.

  2. Step 2: Join the two halves

    Lay both halves face down with the joint flanges together. Seat the M5 hex nuts in the hex traps on one half, then push the M5 socket cap screws through the other half and tighten them into the nuts.

    Ordered a half only? Skip this step.

  3. Step 3: Push the switch in through the faceplate

    Push the switch in through the faceplate opening, back end first, with its bottom toward the side of the faceplate with the Rackify model name, until it stops at the rear of the shelf. The shelf walls hold it without screws.

    TP-Link TL-SG105 mount going into the Rackify mount through the faceplate, back end first
  4. Step 4: Fit the JetKVM (if chosen)

    If you chose a JetKVM position, turn the mount over, then set the JetKVM into its receiver from the back, screen facing out through the faceplate, and fasten it with its 2 supplied screws.

  5. Step 5: Snap in the keystone jacks (if chosen)

    If you chose keystone openings, snap a keystone jack into each one. Jacks are not included.

  6. Step 6: Hold the mount in the rack

    Hold the mount against the rack rails at the position you want, with its holes lined up with the cage nuts or threaded holes.

  7. Step 7: Screw in the rack screws

    Fit a rack screw through each mounting hole and tighten until snug. Use M6 screws with cage nuts on square-hole rails, or #10-32 or #12-24 screws on threaded rails.

Questions

Which rack screws do I need?

Use the screws that match your rack's rails: M6 screws with cage nuts on square-hole rails, or #10-32 or #12-24 screws on threaded rails.

Does the device need screws to stay in the mount?

No. The shelf is sized to the case and holds it without brackets or device screws.

Do I take the feet off the switch?

Yes, if you stuck them on. Most switches come with optional stick-on feet; the shelf is sized to the bare case.

Are keystone jacks included?

No. The openings take standard keystone jacks, which are not included.

Are the JetKVM screws included?

Yes. Each JetKVM position comes with its 2 screws.

How do the two halves join?

With the included M5 socket cap screws and M5 hex nuts: 3 of each per 1U (2 for a 0.5U panel). The nuts sit in hex traps on one half and the screws go through the other half.

What if the mount doesn't fit my device?

If a mount doesn't fit the device it's listed for, we'll replace it or refund it.

View the TP-Link TL-SG105 1U 19-Inch Rack MountAll installation guides →